CE Marking a Robot Cell: Step by Step

Published: Published on Zhilianhai

The sequence

StepOutputOwner
1. Identify applicable directives and regulationsList with reasoningCell builder
2. Gap analysis against each requirementAction listCell builder
3. Risk assessment (ISO 12100)Signed assessmentCell builder
4. Design and safeguardingDrawings, safety conceptCell builder
5. ValidationTest records with measured valuesCell builder
6. Technical fileIndexed documentation setCell builder
7. Declaration of conformity and markingSigned declaration, CE plateCell builder

When a notified body is needed

Most industrial robot cells are self-certified under the machinery rules, but certain categories and certain safety components require a notified body. Check the annexes that apply to your machine type before assuming self-certification is available.

What the technical file should contain

  • Drawings, diagrams and descriptions of the assembly.
  • Risk assessment and the record of risk reduction measures.
  • Standards applied, with the editions.
  • Validation records and measured stopping times.
  • Operating instructions and the declaration of conformity.

Information is provided for initial research. Verify specifications, pricing, policies and standards against the original source before making decisions.