Spotting a Workpiece Frame Mismatch After an Offline Import
Program points depend on the workpiece frame. Check names, the physical installation and axis direction before import, especially for mirrored stations or fixtures that reuse a frame name.

What to check on site
Verify the origin and two independent direction references, then record measured differences from the drawing. If offsets vary with direction, examine orientation and frame conversion first.
Reference
ABB RobotStudio offline programming documentation. The diagram is editorial guidance. Acceptance limits depend on the specific equipment and task.
ZHILIANHAI