Finding the real cause of dropped frames on a trigger camera

Published: Published on Zhilianhai

Basler documentation separates acquisition status from trigger timing; firing the next trigger before the previous frame is done lets frames die in the queue.

Illustrated application scene for industrial vision
Zhilianhai editorial diagram · original Generated category illustration.

How to check it on site

Probe the trigger pulse and the camera ready line on a scope, count pulses against delivered frames for a minute, and a persistent gap proves the trigger is faster than the cycle.