Separating frame orientation from IMU behavior in simulation
An unexpected static reading can come from an IMU frame that is rotated relative to the chassis. Establish the axis relationship before attributing the behavior to the estimator.
How to test it
Capture stationary readings and a single-axis movement. Compare each with the sensor-to-body pose in the model and write down the axis and rotation direction mapping.